NATIVE-C1
NATIVE-C1
1U MTCA.0 Chassis for up to 6 AMCs
  • Form factor: 1U, 19”
  • 1 single full-size NAT-MCH
  • 1 single full-size NAT-PM
  • 1 custom size NAT-JSM
  • 3 single full-size AMCs or 6 single mid-size AMCs

NATIVE-C1

1U MTCA.0 Chassis for up to 6 AMCs

  • Form factor: 1U, 19”
  • 1 single full-size NAT-MCH
  • 1 single full-size NAT-PM
  • 1 custom size NAT-JSM
  • 3 single full-size AMCs or 6 single mid-size AMCs

Description

The NATIVE-C1 offers the performance benefit of µTCA in a space-saving horizontal-mounted 1U height. 6 AMC slots offer users the flexibility to configure for a wide range of applications, such as enterprise, industrial control, telecom, wireless, and others.

Its unique card guide design eases the insertion and removal of AMCs. The replaceable backplane improves the serviceability of the system. As an ordering option, the NATIVE-C1 is available with a 40G Backplane.

The NATIVE-C1 is equipped with high-performance Cooling Units with a total of 80 CFM airflow through the chassis for a better thermal profile.

Key Features

  • Form factor: 1U, 19”, Depth 206mm (230mm with handles)
  • All slots arranged horizontally
  • 1 single full-size NAT-MCH
  • 1 single full-size NAT-PM
  • 1 custom size NAT-JSM
  • 3 single full-size AMCs or 6 single mid-size AMCs

Backplane

  • AMC Ports 0/1: 1GbE routed between MCH and each AMC
  • Port 2/3: Point-to-point SATA/SAS between AMCs
  • AMC Ports 4-7 and 8-11: Fat-Pipe between MCH and each AMC
  • TCLKA, TCLKB, FCLKA: between MCH and each AMC (MCH CKL1, CKL2, CKL3)
  • IPMB_0A, IPMB_0B: between MCH, PM, JSM, CU1/2
  • IPMB_L: between MCH and each AMC
  • JTAG: between JSM, MCH, PM, CU1/2, and each AMC
  • FRU ROM
  • Replaceable backplane, 40G Backplane as option

Cooling Unit

  • 2x Cooling Units (hot-swappable)
  • 4 fans per CU with each fan rated at 20 CFM (total max: 80 CFM)
  • Individual-controlled fan speed
  • Straight through side-to-side cooling
  • Fully managed, redundant, and hot-swappable
  • Monitored fan power for early failure detection
  • Air filter removed detection

Related Products

Order Codes

NATIVE-C1 -[Option]

 

-02

1U 19″ chassis – 2 cooling units – 6 mid/single AMC payload slots, dual GbE, dual fat pipe + standard Backplane
-03  

1U 19″ chassis – 2 cooling units – 6 mid/single AMC payload slots, dual GbE, dual fat + 40G backplane

 

Filler Panels

NATIVE-Filler-B Filler Panel for NATIVE-C1 or NATIVE-C2, closing the gap between the chassis bottom and a full-size AMC, PM, or MCH
NAMC-Filler MS-FP0S  

4 HP MTCA.0 AMC Filler Panel
single mid-size

Solutions / Applications

Various MTCA.0 applications requiring just a reduced number of AMCs.